Titan U glossary

National Fire Danger Rating SystemNFDRS

The National Fire Danger Rating System (NFDRS) is the interagency U.S. system that turns daily weather, fuel and climate information into indices of current and predicted fire danger. The current version, NFDRS2016, replaced the 1978 and 1988 versions.

The National Fire Danger Rating System (NFDRS) is the interagency U.S. system that turns daily weather, fuel and climate information into indices of current and predicted fire danger. The current version, NFDRS2016, replaced the 1978 and 1988 versions.

What it produces

NFDRS is a multiple index system rather than a single number. Its core outputs are the Energy Release Component (ERC), the Burning Index (BI), the Spread Component (SC) and the Ignition Component (IC).

The Spread Component rates the forward rate of spread of a head fire, the Burning Index combines spread with ERC as a measure of intensity, and the Ignition Component relates to the chance that a firebrand starts a fire needing suppression. Dead fuels are tracked in four timelag classes, from fine 1-hour fuels to 1000-hour logs.

A short history

NFDRS began in 1972 and was updated in 1978 and 1988, then stayed fundamentally unchanged for decades. The National Wildfire Coordinating Group (NWCG) approved the NFDRS2016 changes in September 2014 and set January 2021 for all units to complete the transition.

The North Carolina State Climate Office notes that its fire danger estimates and forecasts use NFDRS2016 data for dates on or after 10/01/21.

What changed in 2016

Twenty fuel models were simplified to five, labeled V, W, X, Y and Z. Live herbaceous and woody fuel moisture now comes from the Growing Season Index, which uses weather data to model plant changes such as green-up and removes the need for seasonal manual edits.

Dead fuel moisture for the 1-hour through 1000-hour classes now comes from the Nelson model, which uses temperature, relative humidity, solar radiation and precipitation. Manual entries such as green-up, freeze and dormancy dates and the state of the weather are no longer required, while the same core outputs remain.

What the ratings do not tell you

NFDRS describes broad-area fire danger, not the behavior of a particular fire. NFDRS2016 training material stresses that fire danger outputs cannot quantify actual energy release, spread rate or flame length.

Values are most useful against each station's own history, often as percentiles, and alongside Red Flag Warnings, local fuel observations and drought measures such as the Keetch-Byram Drought Index.

Keep going

How National Fire Danger Rating System connects

Builds on 2

  • Fuel Timelag Classes

    NFDRS builds on fuel timelag classes, tracking dead fuels in four classes from fine 1-hour fuels to 1000-hour logs.

  • Relative Humidity

    NFDRS depends on relative humidity, one of the weather inputs to the model that now supplies its dead fuel moisture values.

Leads to 1

  • Fire Danger Rating

    A fire danger rating is a public summary of the National Fire Danger Rating System, turning its numeric indices into a plain-language level.

Includes 1

  • Energy Release Component

    The Energy Release Component is one of the core outputs of the National Fire Danger Rating System, alongside the Burning Index and others.

Contrasts with 1

  • Fire Behavior

    NFDRS describes broad-area fire danger, while fire behavior is how a particular fire actually acts on its fuels, weather and terrain.

Used to measure 2

  • Fuel Moisture

    Dead fuel moisture is hard to measure in the field, so fire danger ratings estimate it hourly for each size class from weather inputs.

  • Rate of Spread

    Rate of spread is rated in the National Fire Danger Rating System through its Spread Component, which scores the forward spread of a head fire.