The wet-bulb temperature is the lowest temperature air can reach by evaporating water into it until it is saturated. It sits between the air temperature and the dewpoint, and it equals the air temperature when the air is already saturated.
How it is measured
The traditional method wraps a thermometer bulb in a moist muslin wick. Evaporation cools the wet bulb, and the difference between its reading and an ordinary thermometer is used to calculate relative humidity.
It can also be calculated from temperature, relative humidity and pressure, and sounding software can compute a wet-bulb profile through the whole column.
Why winter forecasters lean on it
When precipitation falls into unsaturated air, some of it evaporates and cools the air toward the wet-bulb temperature. The National Weather Service (NWS) office in Louisville advises using the wet-bulb temperature to judge the effect that cooling will have on the eventual temperature.
That is why the wet-bulb profile can point to snow when the thermometer does not. In one Northern California case, NWS Sacramento found a wet-bulb profile well below the temperature profile and below 32°F (0°C) above about 900 mb, and the event turned from rain to snow.
Related heights
The height where the wet-bulb temperature first drops to 32°F (0°C) is the wet-bulb zero, used in both hail and winter forecasting. NWS Amarillo describes it as the height where the evaporatively cooled temperature goes below freezing.
What it does not tell you
The wet-bulb temperature assumes evaporation actually happens. In the Sacramento case it took a little over six hours of evaporating precipitation to bring the melting level near the surface, so light or brief precipitation may not cool the air all the way.
It also describes one level at a time. Warm air aloft that falling snow still has to pass through needs the full sounding.