Wet-Bulb Temperature

The wet-bulb temperature is the lowest temperature air can reach by evaporating water into it until it is saturated. It sits between the air temperature and the dewpoint, and it equals the air temperature when the air is already saturated.

The wet-bulb temperature is the lowest temperature air can reach by evaporating water into it until it is saturated. It sits between the air temperature and the dewpoint, and it equals the air temperature when the air is already saturated.

How it is measured

The traditional method wraps a thermometer bulb in a moist muslin wick. Evaporation cools the wet bulb, and the difference between its reading and an ordinary thermometer is used to calculate relative humidity.

It can also be calculated from temperature, relative humidity and pressure, and sounding software can compute a wet-bulb profile through the whole column.

Why winter forecasters lean on it

When precipitation falls into unsaturated air, some of it evaporates and cools the air toward the wet-bulb temperature. The National Weather Service (NWS) office in Louisville advises using the wet-bulb temperature to judge the effect that cooling will have on the eventual temperature.

That is why the wet-bulb profile can point to snow when the thermometer does not. In one Northern California case, NWS Sacramento found a wet-bulb profile well below the temperature profile and below 32°F (0°C) above about 900 mb, and the event turned from rain to snow.

Related heights

The height where the wet-bulb temperature first drops to 32°F (0°C) is the wet-bulb zero, used in both hail and winter forecasting. NWS Amarillo describes it as the height where the evaporatively cooled temperature goes below freezing.

What it does not tell you

The wet-bulb temperature assumes evaporation actually happens. In the Sacramento case it took a little over six hours of evaporating precipitation to bring the melting level near the surface, so light or brief precipitation may not cool the air all the way.

It also describes one level at a time. Warm air aloft that falling snow still has to pass through needs the full sounding.

Keep going

How Wet-Bulb Temperature connects

Builds on 1

  • Relative Humidity

    Wet-bulb temperature can be calculated from temperature, relative humidity and pressure, and the classic wet-bulb reading is also used to find humidity.

Leads to 2

  • Precipitation Type

    Forecasters judge precipitation type with the wet-bulb temperature when air is unsaturated, because falling precipitation cools dry air by evaporation.

  • Wet-Bulb Zero

    The wet-bulb zero is the height where the wet-bulb temperature first falls to 0 C, so understanding wet-bulb temperature comes first.

Contrasts with 1

  • Dewpoint

    Dewpoint and wet-bulb temperature are easy to mix up, but the wet-bulb temperature sits between the air temperature and the dewpoint.

Used to measure 2

  • Evaporative Cooling

    The wet-bulb temperature marks how far evaporative cooling can take the air, so forecasters use it to judge the cooling that falling precipitation can cause.

  • Rain-Snow Line

    Wet-bulb temperature helps forecasters place the snow level because it accounts for evaporative cooling as precipitation falls into drier air.

Seen in 1

  • Atmospheric Sounding

    Sounding software can compute a wet-bulb profile through the whole column, which winter forecasters use because it often decides rain versus snow.